The plane mask machine can be maintained in accordance with the following aspects and it is necessary to cut off power during the maintenance process:
First, ultrasonic system
Check whether the ultrasonic mask machine system is kept clean, especially the ultrasonic electric box, vibrator (transducer), welding head is necessary to dry cleaning without water, the connecting line is necessary to firm often to check the wear degree of ultrasonic welding head pay attention to observe the change scale of the voltage meter and ammeter pointer on the ultrasonic electric box.
II. Pneumatic system:
The air filter cup of the mask equipment needs to check whether there is water to be discharged, and water should be discharged to the air compressor in the area with high humidity every day. Check whether there is air leakage in all the air cylinder of the air pipe. The location of the magnetic anti-inductor of the air cylinder and whether the operation is normal.
Third, look
Masks are used to wearing on the face, and surgical masks but also need to enter operating room, so the fruit of the masks necessary requirements mask clean cleaning machine equipment, while going off work every day need to arrange personnel to mask after off machine equipment of mesa, cheng fang mask plate for cleaning, is can't go to the clean water, use alcohol such as non-toxic volatile cleaning fluid for cleaning of the equipment.
Four, electrical system
Check and see whether the connection of the circuit of the mask machine is loose, whether the main power line and branch signal line are worn and aging, whether the electrical equipment is loose, whether the electrical box is kept in a dry environment, and whether the exhaust fan is in normal operation.
5. Transmission system
Transmission system includes the motor, gear, gear reducer, sprockets, chains, conveyor belt and other parts, we want to check whether there is a motor attached heat, dust, etc, gear, sprocket, whether there is oil, if there are attachments shall be clean, chain looseness is appropriate if there is any foreign body didn't clean, the transmission have a connection between the screw loose phenomenon, reducer is sufficient lubricating oil, usually in the 1000-1500 hours the machine will need to replace a lubricating oil.
Six, rust
The equipment should not stick to corrosive liquids and objects, and sweat is very likely to lead to rust of equipment parts. If the equipment does not work for a long time, it is necessary to apply anti-rust oil to the transmission system of the mask and the parts that are easy to rust.